Model 2100 Gaussmeter/Teslameter
The Model 2100 is designed to allow maximum flexibility in the use of Hall Probes. Probes supplied for the Model 2100 use a memory chip (EEPROM) that automatically allows the Model 2100 to correct for Hall Probe Element inaccuracies. Probes incorporating temperature sensors are also available. These probes will provide automatic temperature compensation in conjunction with the user defined Hall Probe Temperature Correction feature. The Model 2100 is compatible with probes not using a memory chip (EEPROM). Eight selectable Hall Probe Excitation Currents are available. With a simple connector conversion and a new calibration number, many probes manufactured by Magnetic Instrumentation can be used with this unit without returning it to our factory. However, for optimum accuracy, the probe can be returned for installation of a memory chip (EEPROM). Magnetic Instrumentation offers a wide selection of both axial and transverse probes to measure many different magnet configurations. A Probe Data Sheet is available on request.
FEATURES
Accuracy: DC Specifications ± (% of reading + % of Range)
Range | Design Spec. | Certified To | Range | Design Spec. | Certified To |
300 kG | 0.050+0.020 | 0.100+0.050 | 3000 G | 0.060+0.020 | 0.120+0.050 |
30 kG | 0.050+0.020 | 0.100+0.050 | 300 G | 0.080+0.020 | 0.160+0.050 |
AC (RMS) Specification ± (% of reading + % of Range) (Depending on hall probe frequency response)
Range | 10 Hz – 20 Hz | 20 Hz – 100 Hz | Frequency: 100 Hz-1000Hz | 1000 Hz – 5000 Hz | 5000 Hz – 20 kHz |
300 kG | 1.400+0.500 | 0.700+0.500 | 0.700+0.500 | 0.700+0.500 | 0.800+0.500 |
30 kG | 1.400+0.500 | 0.700+0.500 | 0.700+0.500 | 0.700+0.500 | ~ |
3000 G | 1.600+0.500 | 0.900+0.500 | 0.900+0.500 | ~ | ~ |
300 G | 2.00+0.500 | 1.300+0.500 | ~ | ~ | ~ |
PEAK MODE Specifications ± (% of reading + % of Range)
Range | Rise Time to Peak > 1000 Micro-seconds | 200 to 1000 Micro-seconds | 100 to 200 Micro-seconds |
300 kG | 0.700+0.200 | 0.800+0.200 | 0.900+0.200 |
30 kG | 0.700+0.200 | 0.900+0.200 | 1.000+0.200 |
3000 G | 0.900+0.300 | 1.000+0.300 | 1.500+0.300 |
1.100+0.500 | ~ | ~ | ~ |
Probe Current Specifications ± (% of value)
Value | Design Spec. | Certified To | Value | Design Spec. | Certifed To |
100 mA | 0.050 | 0.080 | -100mA | 0.100 | 0.130 |
50 mA | 0.060 | 0.090 | -50 mA | 0.110 | 0.140 |
25 mA | 0.070 | 0.100 | -25 mA | 0.120 | 0.150 |
12.5 mA | 0.080 | 0.110 | -12.5 mA | 0.130 | 0.160 |
Average Time Constant (Display Rate): This interval may be set from 100 ms to 2500 ms, in 100 ms intervals. (0.4 to 10 Times Per second)
Display Resolution: 4 3/4 Digits (1 part out of 32,000)
Operating Temperature Range: 0°C to +50°C
Storage Temperature Range: -20°C to +70°C
Temperature: ±1.0°C + Accuracy of probe thermistor
Analog Output: ±2% of reading + 10mV + accuracy of selected function
Power Requirements: 110 VAC, 220 VAC @10W, or ±9VDC @5W Operation
Dimensions: Length 12.00 In. (305 mm) Width 6.70 In. (170 mm) Height 2.25 In (57 mm)
Weight: 6 Lbs. (2.7 kg, not including probe)
Display Resolution: 4 3/4 Digits (1 part out of 32,000)
* Specifications subject to change without notice